Filter Results By:

Products

Applications

Manufacturers

Showing results: 121 - 135 of 137 items found.

  • Terminal Mechanical Strength Test

    Aero Nav Laboratories, Inc.

    The terminal strength test is used to performed to determine whether the design of electrical terminals and their method of attachment can withstand mechanical stresses to which they will be subjected during installation or disassembly in equipment. These stresses must be withstood by the component without sustaining damage which would affect either the integrity of the terminals or the operation of the component part itself. Procedures are established in this method for testing, for example wire-lead terminals, flexible-flat-strip or tab-lead terminals, and rigid-type terminals which are threaded or have other arrangements for attaching conductors. The forces applied during the test consist of direct axial, radial or tension pulls, twist, bending torsion, and the torque exerted by the application of nuts or screws on threaded terminals.

  • Insulating Oil Testing

    Megger Group Ltd.

    Insulating oil in electrical power apparatus serves two primary roles, as an insulator and a coolant. As an insulating liquid, oil’s most important property is a high dielectric strength and as a cooling liquid, a low viscosity is paramount. The principal nemeses of insulating oil are oxidation, contamination (particularly moisture, which tends to lower the dielectric properties of insulating oil), and excessive temperature. These enemies are managed through design, regimented installation processes and prudent operation of the oil-filled power apparatus. At all stages of a power asset’s life, testing must be conducted to evaluate the condition of the insulating oil. In fact, for some assets, it can be argued that the oil is tested more frequently than any other component.

  • Current Caliper

    KH23101 - Beijing KeHuan Century EMC Technology Co,.LTD

    The KH23101 current caliper is a toroidal transformer used to measure EMI current. When measuring, the caliper does not directly touch the electrical conductor or the cable under test. The conductor passing through the caliper window is used as the single-turn primary wire of the transformer, and the secondary is designed to be multi-turn. Use with 50 Ω receiving system (such as EMI electromagnetic interference field strength meter or spectrum analyzer). In order to facilitate installation and rapid measurement of EMI current, it is designed as a caliper that can be opened.

  • Engineering Services

    The Test Connection, Inc.

    In addition to the highest quality test programming, maximizing board coverage, and efficient board testing, TTCI offers a full array of other engineering services, including CCA (Circuit Card Assembly) Testing, Design for Test, ASTER TestWay electrical design for test analyzer, Feasa LED analyzer, SMH Technologies FlashRunner in-system programmer, finite element analysus, installation, reverse engineering of Gerber to CAD, Training, Test System PC, Hardware, and Software Upgrades, and more.

  • Clamp On Meters

    Triplett Test Equipment & Tools

    1000A True RMS AC/DC clamp-on meter with a backlit LCD display. It offers a large variety of measurement features including AC/DC Current, AC/DC Voltage, Resistance, Temperature, Capacitance, Continuity, Diode Test and NCV Detector. The rubberized overmolded housing provides impact and drop resistance in a sleek ergonomic design, and the user-friendly Auto Power Off feature helps maximizes battery life. With a CAT III 600V design, it provides superior resistance to damage from transient overvoltages in any demanding industrial setting. The Model 9325 is suited for a variety of industrial and residential applications such as security, electrical, HVAC installations and more. Includes test leads, Type K Temperature probe, 9V battery, and case.

  • Partial Discharge Testing Equipment

    AR700 - Scope T&M Pvt, Ltd.

    PD Defect Location in High-Voltage Equipment Insulation by Acoustic Sensors To act on deteriorating insulation the source of PD must be known.The insulation defects produce partial discharges, which emits electrical impulses, radiation of electromagnetic waves as well as acoustic signals.The AR700 measures acoustic signals with multiple sensors spread over the transformer. Then the software determines the failure location using the time difference of all incoming signals. Finally, these coordinates are shown in a 3D model of the transformer. AR700 device is used for measuring of acoustic signals on the external surfaces of gas-insulated breakers and substations, power transformers and other tank high-voltage equipment. The acoustic signals are caused by partial discharges in the insulation, which is the sigh of the defects.The advantage of “AR700” device is the quick installation of the acoustic PD sensors on the external surface of high-voltage equipment tank. The sensors have magnetic holder that is why there is no need to de-energize the equipment for the sensors installation. “AR700” device has 4 syn-chronic channels for acoustic signal measurement. This gives the possibility not only to find the defects in the insulation, but also to locate them. The location function of the “AR700”device is unique for acoustic devices.

  • Megohmmeter Insulation Tester

    AMIC-30 - Amperis sl

    The AMIC-30 insulation tester is a small portable meter designed to measure insulation resistance in electrical and telecommunications installations, cables, motors, transformers and other equipment. The test voltage can be programmed in steps from 10 V to 1000 V. The instrument can measure both insulation resistance over a wide range (0,1kΩ...100GΩ), and insulation leakage current, capacitance and other parameters. All test results can be stored in the internal memory and sent to a computer via the included wireless USB receiver. The meters are supplied with rechargeable Ni-Cd batteries.

  • Gauss Meters

    PCE Instruments

    A gauss meter displays electromagnetic wave measurements in Gauss (G), milliGauss (mG), milliTesla (mT) or microTesla (µT) units. A gauss meter can detect either static (DC) permanent (rare-earth) magnetic or dynamic (AC) electromagnetic fields (EMFs), or both. Thus, it is important to review the specifications of a gauss meter prior to purchase to ensure suitability for the intended application.Neodymium (NdFeB) permanent magnets are among the world's strongest and most widely used magnets. When testing magnets made of neodymium or other rare-earth elements, a gaussmeter or magnetometer capable of measuring DC magnetic fields is required. However, most electromagnetic fields encountered are generated by AC currents. Examples include electrical power lines, transformers and wiring for overhead lighting, solar panels and other electrical devices and equipment. Electromagnetic fields from electrical installations are believed to cause feelings of nervousness, anxiety and paranoia in EMF-sensitive human beings.Most gaussmeters offered by PCE Instruments can be calibrated and certified according to DIN ISO 9000 standards for an additional fee. Replacement gaussmeter probes and optional accessories are available for most gaussmeter models.

  • Flexible Current Sensor Probe

    CTA - Powertek LLC

    The CTA current sensors convert ac current to an isolated 0-5A current with available ranges from 100A to 10,000A. Because the current sensors are flexible split core, installation is possible without shutting down the LV electrical supply, avoiding expensive down-time costs. Typical applications are retrospective energy monitoring in factories, offices buildings, process control data logging systems, where power, energy and current monitoring is important. Typical applications are factories, offices buildings, ac/dc VFD drives, welding, power conversion and power distribution. For all CTA current sensor models, a NIST/NPL (UKAS) traceable calibration certificate and certificate of conformance is supplied. All CTA sensors use UL94V0 or CSA approved materials. The CTA flexible current sensors are suited to permanent or semi permanent installation. The coil sensor is durable, lightweight, flexible and will easily clip-around a power cable. The 5A output from the CTA current sensor connects direct to installed metering, rotary metering or current transducers.

  • AC Dielectric Test Systems

    700-DI - Hipotronics

    The HIPOTRONICS standard line of AC Dielectric Test Systems are designed to perform high voltage AC tests on electrical apparatus in accordance with IEC60, IEEE 4 and IEC 270 and other national test standards. A variety of mechanical configurations are available to suit different installation conditions. Some models can be supplied in mobile versions when it is difficult to move the test object to the test area. AC Dielectric Test Sets are available in a wide range of voltage and power ratings with exceptional reliability, durability and functionality. No matter what your requirement is, HIPOTRONICS has an affordably priced, highly reliable test solution to meet your needs.

  • Solar Pump Inverter

    45-100kw - Shenzhen Setec Power Co., Ltd.

    Solar pumping system is composed of a solar array,a pump and a solar pumping inverter. Based on the design philosophy that it is better to store water than electricity , there is no energy storing device such as storebattery in the system. The solar array,an aggregation of many solar modules connected in series and parallel , absorbs sunlight radiation and converts it into electrical energy , providing dynamical water for the whole system. The pumping inverter controls and adjusts the system operation and converts the DC produced by solar array into AC to drive the pump , and adjust the output frequency intensity to realize the maximumpower point tracking (MPPT) . The pump, drive by 3-phase AC motor,can draw water fromthe deep wells or rivers and lakes to pour into the storage tank or reservoir , or directly connect to the irrigation system ,fountain system,ect. According to the actual systemdemand and installation conditions,different types of pump such as centrifugal pump, axial flow pump,mixed-flow pump or deep-well pump can be used.

  • Solar Pump Inverter

    22-37kw - Shenzhen Setec Power Co., Ltd.

    Solar pumping system is composed of a solar array,a pump and a solar pumping inverter. Based on the design philosophy that it is better to store water than electricity , there is no energy storing device such as storebattery in the system. The solar array,an aggregation of many solar modules connected in series and parallel ,  absorbs sunlight radiation and converts it into electrical energy , providing dynamical water for the whole system. The pumping inverter controls and adjusts the system  operation and converts  the  DC produced  by  solar array  into  AC  to drive the pump ,  and adjust  the output  frequency  intensity to realize the maximumpower point tracking (MPPT) . The pump, drive by 3-phase AC motor,can draw water fromthe deep wells or rivers and lakes to pour  into the storage tank or reservoir , or directly connect to the irrigation system ,fountain system,ect. According to the actual systemdemand and installation conditions,different types of pump such as centrifugal pump, axial flow pump,mixed-flow pump or deep-well pump can be used.

  • Microwave Power Modules

    S-BAND to KA-BAND - Communications & Power Industries

    Each of CPI TMD's TWT-based units is comprised of a compact power supply and mini TWT, combined into an ultra-compact, lightweight "drop-in" amplifier block. This simplifies system design and installation, increases reliability and minimizes safety hazards. The units also feature high electrical efficiency and excellent thermal management. Performance is factory set, removing the need for any user adjustments in the field and, if necessary, permitting easy field replacement of the complete unit. The product range covers S-band to Ka-band, and includes continuous wave (CW), pulsed and CW/pulsed units of extremely compact design. At only 1.7 kg with over 110 W output power, the PTXM1000 is believed to be the market’s highest power density MPM.

  • HV Enclosures with Integrated Safety Test

    LXinstruments GmbH

    The HV test hood according to Performance Level e (ISO 13849-1), developed by us according to the EN50191 standard (erection and operation of fixed and temporary electrical test installations), offers the highest safety for the operator. The large test chamber is enclosed with a hood made of sturdy, highly insulating and transparent plastic. During the test, there is a clear view of the test specimen. A signal light visually indicates safe opening when the light is “green”. “Red light” symbolises danger, the hood cannot be opened due to the safety interlock. The safety switch also ensures that the hood cannot be opened during the test. This means that the test hood fulfils all the required specifications for compulsory contact protection.

  • Flexible Rope-Type Current Probe

    RCT1A and RCT5A - Powertek LLC

    These probes have great bandwidth ensuring accurate measurement even with harmonically distorted wave shapes. For all RCT1A/RCT models, a NIST, NAVLAP, NPL (UKAS) factory traceable calibration certificate and certificate of conformance is supplied. UL/CSA approved materials are used throughout. Three phase and single phase flexible AC current sensors (rope sensors) are available for fast installation in confined spaces, eliminating the need for Electrical Supply Shutdown. Available outputs are 1A @ 2.5VA and 5A @ 0.5VA, this means long cable lengths from current sensor to signal conditioner allow these low VA ratings to be used, even when feeder cable to energy meter distances are large (up to 98 feet / 30 meters)